Riata® ST OptimTM Defibrillation Lead

Feel the Difference

Riata ST Optim leads are highly advanced tachycardia pacing leads, with an overlay of St. Jude Medical’s innovative Optim insulation and a design intended to ease implant, and promote reliability.

Riata ST Optim Pacing Lead 

Features & Benefits

Optim Insulation

  • Innovative Optim® insulation material is the first silicone-polyurethane copolymer insulation designed for cardiac lead use. It blends the best features of polyurethane and silicone for improved handling and increased durability.

Greater Ease at Implant

  • One of the thinnest defibrillation leads available: Can be inserted using a 7 F introducer.
  • Active mapping collar: Facilitates quick confirmation of suitable lead placement.
  • Enhanced fluoroscopic visibility: Eases confirmation of tip placement and verification of helix extension/retraction.
  • Fast-Pass® coating: Enables smooth placement through the introducer and veins.

Reliability

  • Flat outer wire and silicone back-filled coils: Flat outer wire provides a low profile for defibrillation coils, and silicone back-filled coils are designed for the reduction of tissue in-growth.
  • Redundant conductor cables: Provide added safety margin.
  • TiN (titanium nitride) fractal coating: Designed to provide precise sensing and improved contact with the myocardium.
  • Steroid elution: Designed to reduce inflammation at the lead/tissue interface, resulting in lower acute and chronic stimulation thresholds.

Clinical Information

Safety & Indications

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

Please see the physician’s manual for appropriate devices for indications, contraindications, warnings, precautions and potential adverse events.

Product Comparison

Reimbursement Information

Product Components

Demonstration Video

Technical Specifications

Models

7020
Active fixation (extendable/retractable helix)
True bipolar/dual coil
Tip-to-proximal coil spacing—17 cm
60, 65, 75 cm length
 
7021
Active fixation (extendable/retractable helix)
True bipolar/dual coil
Tip-to-proximal coil spacing—21 cm
60, 65, 75 cm length
 
7022
Active fixation (extendable/retractable helix)
True bipolar/single coil
60, 65, 75 cm length

7070
Passive fixation
True bipolar/dual coil
Tip-to-proximal coil spacing—17 cm
60, 65, 75 cm length
 
7071
Passive fixation
True bipolar/dual coil
Tip-to-proximal coil spacing—21 cm
60, 65, 75 cm length