Promote Accel™ CRT-D

This device is commercially available for use in the United States and select international markets.

Automatically Adjusts To Changing Patient Needs For Optimal Therapy Delivery

The Promote Accel CRT-D is designed to reduce life-threatening risks for heart failure patients and simplify the implant, monitoring and follow-up processes for re-synchronizing heart rhythms.

The Promote Accel CRT-D features capture confirmation, biventricular trigger mode and AT/AF alerts monitoring, which allow physicians to tailor therapy to changing patient needs. This helps ensure optimal therapy delivery and enable timely remote patient follow-up for safer, more efficient patient care. Promote Accel CRT-D device features include:

SJ4 Connector

The SJ4 Connector with a single terminal pin connection that can decrease chances of lead-to-port mismatch. Fewer connections and setscrews lessen complexity, and the improved terminal pin visibility is designed to encourage proper lead connection.

BiVCap™ Confirm

Automatic pacing adjustments meet changing patient needs.

  • Automatically, periodically and independently measures and trends capture thresholds of both the right and left ventricles
  • Minimizes risks associated with unpredictable changes in capture thresholds
  • Provides reliable, automatic pacing adjustment

ACap™ Confirm

Automatic output adjustments deliver optimal therapy and help ensure improved patient results.

  • Utilizes an enhanced algorithm that increases the algorithm usage recommendation rate and does not require separate set-up tests
  • Captures threshold trend data to streamline follow-up
  • Provides reliable automatic pacing output adjustment

BiV Trigger Mode

Triggered pacing ensures BiV therapy and maintains delivery of cardiac resynchronization therapy.

  • Triggers pacing in response to a sensed event
  • Ensures BiV therapy delivery during atrial arrhythmias

AT/AF Alerts

Alerts provide valuable insight into patient status.

  • Provide an AT/AF burden alert when program threshold is exceeded
  • Provide an AT/AF alert when continuous episode duration exceeds threshold
  • Offer enhanced notification capabilities through both vibratory patient notifier and Merlin™ Patient Care System

Promote Accel CRT-D

Model

CD3215-36Q  CD3215-30  CD3215-36
Telemetry RF  RF  RF
Delivery Energy 36 J  30 J  36 J
Volume (cc) 42  39  43
Weight (g) 82  76  82
Size (mm) 75x50x14  80x50x13  81x50x14
Defibrillation Lead Connections SJ4  DF-1  DF-1
Sense/Pace Lead Connections IS-1; SJ4  IS-1  IS-1
High Voltage Can Electrically active titanium can  Electrically active titanium can  Electrically active titanium can

Specification Sheets

Promote Accel CRT-D with SJ4 Connector Spec Sheet [PDF] 

Promote Accel CRT-D with DF-1 Connector Spec Sheet [PDF]

SJ4 Technical Guide [PDF]